Home
Product Catalog
Custom Page1
Custom Page2
Custom Page3
Documents
Contact Us

Product Catalog 

 

GSM BASE

Model No.︰GSM-II
Brand Name︰SENGGANG
Country of Origin︰China
Minimum Order︰-
Share on:

 Total 152 Related Items 
Prev7071727374Next

Product Description
GSM-III Alarm

1,GSM-III alarming controller (5 group)
2,inactive infrared intruding detector (up to 10)
3,wireless magnetic detector (up to 10)
4, cordless remote controller (two or more)
5, have 5 group dialing (two time in turn), voice alarm and live monitor
6, remote control and emergency alarm
7,moniter the voice in home when alarm
---------------------------
HOW WE ENTER THE PHONE NUMBERS TO DIAL?
The GSM system need SIM card to dial. So, you can use your own mob-phone to program it, you can set 5 phone number in SIM card, be sure in first (1,2,3,4,5) position in the SIM card, which 5 number is to be dial out when alarm is happen.
1). POWER ON
When you set the SIM card (have first 5 number) into the GSM base, connect power on, which need 9V—12V DC, must be over 1000mA current. The lamp on panel will bright on green
You can set any one detector to the system when the GSM base start power on in 20 second. After 20 second, the system will not set any detector into the base.
-------You needn’t do below, for we have set all sample detectors into the base.
2). When you wand to set Wireless Infra Red Detector in the system, you can open the power of Wireless Infra Red Detector, the system will send out a whisper, the lamp on panel will flash on red. It is ok.
3). When you wand to set Wireless Magnetic door detector in the system, you make Wireless Magnetic door detector work, the system will send out a whisper also. The lamp on panel will flash on red. It is ok too.
4). Two of the remote controller have set into the system, you don’t need to set again, but if you want to set, you can do as this: push the button (^) on the first remote controller, the system will send out a whisper, and push the button (^) on the second remote controller, the system will send out a whisper also. The lamp on panel will flash on red. These two remote controllers have set into the base.
5). When you end the system set, after 20 second, you can test the system
6). The remote controller has four buttons; button1, set alarm work;button2, set alarm off; button3, set emergency call;button4 (set into base). If you push button2 and button4 at same time,
You will hear: 3 ‘ Bi’ show alarm sound out is off; 1 ‘ Bi’ show alarm sound out is on
7). You can dial in (your SIM card number) and inter password (1 2 3 4 #) to monitor the voice in alarm place when every thing is ready.
8) There is 2- wire (gray; purple) outside the base; every one can be set to ground (black) to make alarm out.
9) .2 -wire for outside sound alarm (black -; yellow +), this connect to the sound alarm, black wire (-) to the black wire; yellow wire (+) to the red of the sound alarm.
10). 3 -wire for output, (1#--white; 2#--blue; 3#--green), you can make it on or off by outside phone in to control it.
11). When you wand to exit all the detector in system, please turn off the power, and push the key on panel (beside left, a small hole), then, put on the power, after 3 second, the lamp on panel will flash on red, it is ok.

HOW WE CONTROLL THE GEM-II BASE BY OUTSIDE PHONE?
Pick up the phone and dial to the GSM-II base, you will hear “ Bi “, then inter password 1 2 3 4 #, (1234 is first code in the base), you hear a short “ Bi “, this means you can hear the voice in the alarm place and you can operate the base:
A) dial 0 # ,alarm on(detector use);dial 0 * ,alarm off(detector no-use);A long “ Bi “ show operates successful.
B) dial 1 # ,output 1(white) on (+5V);dial 1 * ,output 1(white) off (0V);A long “ Bi “ show operates successful.
C) dial 2 # ,output 2 (blue ) on (+5V);dial 2 * ,output 2 (blue ) off (0V);A long “ Bi “ show operates successful.
D) dial 3 # ,output 3 (green) on (+5V);dial 3 * ,output 3 (green) off (0V);A long “ Bi “ show operates successful.
E) Dial 8 #, a short “ Bi “ show you inter new password, you may dial 8 0 0 0 #. ;A long “ Bi “ show operates successful. That is change password from 1234 to 8000
F) Dial 9 #, set sound out on 3 min; dial 9 *, set sound out off when alarm; a long “ Bi “ show operate successful.
Note: when you answer the GSM-II base (when alarming out), you do not need to inter password, you can hear the voice in the alarm place and you can operate the base as above do.
-------------------------------------
Note:
A-- when every first time power on, the system will waiting for you to set any one detector, and the lamp on panel will all height on. If you not do this again, please wait 30 second, the base auto inter into alarm state, the lamp on panel will flash on green. Then you can test it.
B-- when you have not set 5 number to the system, the lamp on panel will bright on green, when you have set 3 number to the system, the lamp on panel will flash on green.
C-- when alarm happen or you call in to monitor, the lamp on panel will flash on red.
D-- the longer white wire is antenna for controller.
E---3output pin go high (+5V) or low (0V) as you set, you can connect with other circuit to control Ready.
Product Image


Related Products
CDMA DIGITAL TRUCKING  HANDSET
CDMA DIGITAL TRUCKING HANDSET
CDMA Transceiver
CDMA Transceiver
Transceiver SG-1000
Transceiver SG-1000
Wireless intercom system PZ-2000
Wireless intercom system PZ-2000

Home  |  Product Catalog  |  Custom Page1  |  Custom Page2  |  Custom Page3  |  Documents  |  Contact Us  |  Sitemap  |  Mobile Version
  简体版     繁體版     English